By the MassBid Estimation team · Reviewed by a senior estimator with 10+ years of experience · Published · Updated
In short
Construction drawing abbreviations are short forms used on plans, sections, schedules and notes. The most common are TYP (typical: applies everywhere the condition repeats), UNO (unless noted otherwise), AFF (above finished floor), O.C. (on center), NIC (not in contract), NTS (not to scale), SIM (similar), EQ (equal) and T/ and B/ (top of and bottom of). Several mean different things on different sheets, such as EF (each face on structural, exhaust fan on mechanical) and RCP (reflected ceiling plan or reinforced concrete pipe), so the set's own abbreviation legend, usually on the first general or architectural sheet, always wins.
- Where the legend is
- First general (G) or architectural (A) sheet, sometimes on each discipline's first sheet
- Most used
- TYP, UNO, AFF, O.C., SIM, EQ, NTS, NIC, T/ and B/
- UNO (U.N.O., UON)
- Unless noted otherwise: the default for the sheet unless a note says different
- Changes the price
- NIC, FBO, OFCI, ALT, EXIST, EW, EF, T&B, TYP
- Mean two things
- EF, EA, RCP, PT, SD, CB, WP, W, WC, FD
- Rebar callouts
- #5 @ 12" O.C. EW T&B = #5 bars, 12 in. apart, both ways, top and bottom
- In this list
- 271 abbreviations across seven disciplines
Search the abbreviation list
Type an abbreviation or a word, or filter by discipline. Each entry is filed under the discipline whose sheets use it most; where the same letters mean something else on another discipline's sheets, the note says so.
Abbreviation lookup
271 of 271 abbreviations
| Abbr. | Meaning |
|---|---|
| (N) | NewGeneral |
| (R) | Remove or relocateCheck the legend; firms use it both waysGeneral |
| @ | AtSpacing, as in #5 @ 12" O.C.General |
| A or AMP | AmpereElectrical |
| AB | Anchor boltStructural |
| AC | Asphalt concreteAlso air conditioning on mechanical sheetsCivil and site |
| ACP | Acoustical ceiling panelArchitectural |
| ACT | Acoustical ceiling tileArchitectural |
| ADA | Americans with Disabilities ActArchitectural |
| AFCI | Arc-fault circuit interrupterElectrical |
| AFF | Above finished floorMounting heights of outlets, switches, fixtures and accessoriesGeneral |
| AFG | Above finished gradeGeneral |
| AHU | Air handling unitMechanical |
| AIC | Ampere interrupting capacityElectrical |
| ALT | AlternateA bid alternate is priced separately from the base bidGeneral |
| ALUM | AluminumArchitectural |
| APPROX | ApproximateGeneral |
| ARCH | Architect or architecturalGeneral |
| ASI | Architect's supplemental instructionGeneral |
| ATS | Automatic transfer switchElectrical |
| B/ | Bottom ofAs in B/FTG, bottom of footingStructural |
| BC | Back of curb, or bottom of curbCivil and site |
| BD | BoardArchitectural |
| BFP or BFV | Backflow preventerPlumbing and fire |
| BLDG | BuildingGeneral |
| BM | BenchmarkCivil and site |
| BMP | Best management practiceStormwater and erosion controlCivil and site |
| BOD | Basis of designThe named product others must equalGeneral |
| BOF | Bottom of footingStructural |
| BOT | BottomStructural |
| BRG | BearingStructural |
| BRK | BrickArchitectural |
| BTU or BTUH | British thermal units (per hour)Mechanical |
| BW / TW | Bottom of wall / top of wallRetaining wall gradesCivil and site |
| C | ConduitElectrical |
| C&G | Curb and gutterCivil and site |
| CB | Catch basinCivil and site |
| CB | Circuit breakerCatch basin on civil sheetsElectrical |
| CD | Ceiling diffuserMechanical |
| CFM | Cubic feet per minuteMechanical |
| CI | Cast ironPlumbing and fire |
| CIP | Cast-in-place concreteStructural |
| CJ | Control jointArchitectural |
| CJP | Complete joint penetration weldStructural |
| CKT | CircuitElectrical |
| CL or ℄ | CenterlineGeneral |
| CLG | CeilingArchitectural |
| CLR | Clear or clearanceGeneral |
| CMP | Corrugated metal pipeCivil and site |
| CMU | Concrete masonry unitConcrete blockArchitectural |
| CO | CleanoutPlumbing and fire |
| COL | ColumnArchitectural |
| CONC | ConcreteStructural |
| CONT | ContinuousGeneral |
| CONTR | ContractorGeneral |
| CPT | CarpetArchitectural |
| CT | Ceramic tileArchitectural |
| CUH | Cabinet unit heaterMechanical |
| CW | Cold waterPlumbing and fire |
| CWS / CWR | Chilled water supply / returnMechanical |
| DCVA | Double check valve assemblyPlumbing and fire |
| DET or DTL | DetailGeneral |
| DF | Drinking fountainArchitectural |
| DIA or Ø | DiameterGeneral |
| DIM | DimensionGeneral |
| DIP | Ductile iron pipeCivil and site |
| DL | Dead loadStructural |
| DN | DownGeneral |
| DS | DownspoutArchitectural |
| DWG | DrawingGeneral |
| DWL | DowelStructural |
| DWV | Drain, waste and ventPlumbing and fire |
| DX | Direct expansionMechanical |
| EA | EachGeneral |
| EA | Exhaust airOn general notes EA means eachMechanical |
| EF | Each faceRebar on both faces: double the bar countStructural |
| EF | Exhaust fanOn structural sheets EF means each faceMechanical |
| EG | Existing gradeCivil and site |
| EIFS | Exterior insulation and finish systemArchitectural |
| EJ | Expansion jointArchitectural |
| EL or ELEV | ElevationA height above a datum, or an elevation viewGeneral |
| EM | EmergencyEmergency lighting and circuitsElectrical |
| EMT | Electrical metallic tubingElectrical |
| EOP | Edge of pavementCivil and site |
| EPDM | Ethylene propylene diene monomer roofingArchitectural |
| EQ | EqualSpace equallyGeneral |
| ERV | Energy recovery ventilatorMechanical |
| EW | Each wayBars both directions: take off bothStructural |
| EWC | Electric water coolerPlumbing and fire |
| EXIST or (E) | ExistingExisting work is usually not in the new-work takeoffGeneral |
| EXT | ExteriorArchitectural |
| FACP | Fire alarm control panelElectrical |
| FBO | Furnished by othersExcluded from your material priceGeneral |
| FCO | Floor cleanoutPlumbing and fire |
| FCU | Fan coil unitMechanical |
| FD | Fire damper, or floor drainFloor drain on plumbing sheetsMechanical |
| FDC | Fire department connectionPlumbing and fire |
| FDN | FoundationStructural |
| FE | Fire extinguisherArchitectural |
| FEC | Fire extinguisher cabinetArchitectural |
| FF | Finished floorGeneral |
| FFE | Finished floor elevationCivil and site |
| FG | Finished gradeCivil and site |
| FH | Fire hydrantCivil and site |
| FIN | FinishGeneral |
| FL | Flow lineCivil and site |
| FRP | Fiberglass reinforced panelArchitectural |
| FRT | Fire-retardant treatedUsually plywood or lumberArchitectural |
| FS | Floor sinkPlumbing and fire |
| FSD | Fire smoke damperMechanical |
| FTG | FootingStructural |
| FV | Field verifyGeneral |
| GA | GaugeMetal stud and sheet metal thicknessArchitectural |
| GALV | GalvanizedArchitectural |
| GB | Grade beamStructural |
| GC | General contractorGeneral |
| GFCI or GFI | Ground-fault circuit interrupterElectrical |
| GI | Grease interceptorPlumbing and fire |
| GLB or GLULAM | Glued laminated timberStructural |
| GND or G | GroundElectrical |
| GPM | Gallons per minutePlumbing and fire |
| GWB or GYP BD | Gypsum wallboardDrywallArchitectural |
| HB | Hose bibbPlumbing and fire |
| HC | Hollow core or handicappedRead it from context: doors or accessibilityArchitectural |
| HDPE | High-density polyethylene pipeCivil and site |
| HM | Hollow metalSteel doors and framesArchitectural |
| HMA | Hot mix asphaltCivil and site |
| HSS | Hollow structural sectionSteel tube or pipe sectionStructural |
| HT or HGT | HeightGeneral |
| HW / HWR | Hot water / hot water recirculationPlumbing and fire |
| HWS / HWR | Heating hot water supply / returnMechanical |
| IG | Isolated groundElectrical |
| INSUL | InsulationArchitectural |
| INT | InteriorArchitectural |
| INV or IE | Invert elevationInside bottom of a pipe; sets trench depthCivil and site |
| J or JB | Junction boxElectrical |
| JAN | JanitorArchitectural |
| JST | JoistStructural |
| KSI | Kips per square inchStructural |
| KVA | Kilovolt-ampereElectrical |
| KW | KilowattElectrical |
| L | Steel angleAs in L4x4x3/8Structural |
| LAM | Laminate or laminatedArchitectural |
| LAV | LavatoryPlumbing and fire |
| LL | Live loadStructural |
| LLH / LLV | Long leg horizontal / long leg verticalStructural |
| LP | Lighting panelElectrical |
| LVL | Laminated veneer lumberStructural |
| LVT | Luxury vinyl tileArchitectural |
| MAU | Makeup air unitMechanical |
| MAX | MaximumGeneral |
| MB | Machine boltStructural |
| MC | Metal-clad cableElectrical |
| MCB | Main circuit breakerElectrical |
| MDP | Main distribution panelElectrical |
| MFR | ManufacturerGeneral |
| MH | ManholeCivil and site |
| MIN | MinimumGeneral |
| MISC | MiscellaneousGeneral |
| MLO | Main lugs onlyElectrical |
| MO | Masonry openingArchitectural |
| MSB | Main switchboardElectrical |
| MTL | MetalArchitectural |
| NIC | Not in contractShown for reference only; do not price itGeneral |
| NL | Night lightElectrical |
| NTS | Not to scaleDo not measure it; use the written dimensionsGeneral |
| O.C. | On centerSpacing measured center to centerGeneral |
| OA | Outside airMechanical |
| OFCI | Owner furnished, contractor installedPrice the labor, not the materialGeneral |
| OFOI | Owner furnished, owner installedGeneral |
| OPP | OppositeGeneral |
| OS | Occupancy sensorElectrical |
| PC / PT | Point of curvature / point of tangencyCivil and site |
| PEX | Cross-linked polyethylene pipePlumbing and fire |
| PL | PlateAs in PL 1/2 x 8Structural |
| PLAM | Plastic laminateArchitectural |
| PNL or PP | Panel, or power panelElectrical |
| PRV | Pressure reducing valvePlumbing and fire |
| PSF | Pounds per square footGeneral |
| PSI | Pounds per square inchGeneral |
| PSL | Parallel strand lumberStructural |
| PT | Paint, or porcelain tileOn structural sheets PT means post-tensioned or pressure-treatedArchitectural |
| PT | Post-tensioned, or pressure-treatedConcrete slabs, or lumberStructural |
| PTD | PaintedArchitectural |
| PVC | Polyvinyl chloride pipePlumbing and fire |
| PVI | Point of vertical intersectionCivil and site |
| QT | Quarry tileArchitectural |
| RA | Return airMechanical |
| RB | Rubber baseArchitectural |
| RCP | Reflected ceiling planArchitectural |
| RCP | Reinforced concrete pipeOn architectural sheets RCP is the reflected ceiling planCivil and site |
| RD | Roof drainArchitectural |
| REF | ReferenceGeneral |
| REINF | Reinforcing or reinforcementStructural |
| REQD | RequiredGeneral |
| REV | RevisionGeneral |
| RFI | Request for informationGeneral |
| RG | Return grilleMechanical |
| RGS or GRC | Rigid galvanized steel conduitElectrical |
| RO | Rough openingArchitectural |
| ROW | Right of wayCivil and site |
| RPZ | Reduced pressure zone backflow preventerPlumbing and fire |
| RTU | Rooftop unitMechanical |
| SA | Supply airMechanical |
| SC | Solid coreWood doorsArchitectural |
| SD | Storm drainCivil and site |
| SD | Smoke damper, or smoke detectorStorm drain on civil sheetsMechanical |
| SH | ShowerPlumbing and fire |
| SIM | SimilarSame as the referenced detail, with minor differencesGeneral |
| SK | SinkPlumbing and fire |
| SOG | Slab on gradeStructural |
| SOMD | Slab on metal deckStructural |
| SP | Static pressureMechanical |
| SPEC | SpecificationGeneral |
| SPR | SprinklerPlumbing and fire |
| SQ | SquareGeneral |
| SS or SAN | Sanitary sewerCivil and site |
| SSM | Solid surface materialArchitectural |
| STA | Station10+50 means 1,050 ft along the baselineCivil and site |
| STC | Sound transmission classArchitectural |
| STD | StandardGeneral |
| STIFF | StiffenerStructural |
| STL | SteelArchitectural |
| STOR | StorageArchitectural |
| STRUCT | StructuralStructural |
| SWBD | SwitchboardElectrical |
| SWPPP | Stormwater pollution prevention planCivil and site |
| T/ | Top ofAs in T/STL, top of steelStructural |
| T&B | Top and bottomGeneral |
| T&G | Tongue and grooveArchitectural |
| TBD | To be determinedGeneral |
| TC | Top of curbCivil and site |
| THHN | Thermoplastic high heat-resistant nylon-coated wireElectrical |
| TOB / BOB | Top of bank / bottom of bankCivil and site |
| TOC | Top of concreteStructural |
| TOF | Top of footingStructural |
| TOS | Top of steel, or top of slabStructural |
| TOW | Top of wallStructural |
| TP | Top of pavementCivil and site |
| TPO | Thermoplastic polyolefin roofingArchitectural |
| TSTAT or T | ThermostatMechanical |
| TVSS or SPD | Surge protective deviceElectrical |
| TYP | TypicalApplies everywhere the same condition occurs, not just where notedGeneral |
| UG | UndergroundElectrical |
| UNO | Unless noted otherwiseGeneral |
| UR | UrinalPlumbing and fire |
| V | VoltElectrical |
| V or VTR | Vent, or vent through roofPlumbing and fire |
| VAV | Variable air volume boxMechanical |
| VB | Vapor barrierArchitectural |
| VCT | Vinyl composition tileArchitectural |
| VFD | Variable frequency driveMechanical |
| VIF | Verify in fieldGeneral |
| VRF | Variable refrigerant flowMechanical |
| VWC | Vinyl wall coveringArchitectural |
| W | Wide flange steel beamW12x26: 12 in. nominal depth, 26 lb per footStructural |
| W | Watt, or wireOn structural sheets W is a wide flange beamElectrical |
| W/ | WithGeneral |
| W/O | WithoutGeneral |
| WC | Water closet or wall coveringRead it from context: toilet or finishArchitectural |
| WCO | Wall cleanoutPlumbing and fire |
| WD | WoodArchitectural |
| WH | Water heaterPlumbing and fire |
| WHA | Water hammer arrestorPlumbing and fire |
| WM | Water main or water meterCivil and site |
| WP | WaterproofingArchitectural |
| WP | WeatherproofWaterproofing on architectural sheetsElectrical |
| WRB | Weather-resistive barrierArchitectural |
| WT | Structural tee cut from a W shapeStructural |
| WWF or WWR | Welded wire fabric or reinforcementStructural |
| XFMR or T | TransformerElectrical |
Abbreviations that change what you price
Most abbreviations just save space. These change the quantity or the scope, and missing one is a common cause of a bid that is too high or too low.
| Abbr. | Meaning | What it does to the estimate |
|---|---|---|
| NIC | Not in contract | Shown for coordination only. Leave it out of the takeoff. |
| FBO | Furnished by others | Leave out the material; check whether you still install it. |
| OFCI | Owner furnished, contractor installed | Price the installation labor, not the material. |
| ALT | Alternate | Price it separately from the base bid, as the bid form asks. |
| EXIST / (E) | Existing | Not new work, unless the notes say to remove, patch or match it. |
| TYP | Typical | The detail applies at every similar condition, not only where it is drawn. Count them all. |
| SIM | Similar | Same as the referenced detail with small differences. Check the differences before copying quantities. |
| UNO | Unless noted otherwise | The default for the whole sheet. Find the exceptions before measuring. |
| EW | Each way | Reinforcing runs in both directions. Take off both. |
| EF | Each face | Reinforcing on both faces of a wall. Double the bars. |
| T&B | Top and bottom | Two mats of reinforcing. Double the bars. |
| NTS | Not to scale | Never scale it. Use the written dimensions. |
| VIF / FV | Verify in field | The dimension may change. Note it as an assumption in the bid. |
Abbreviations that mean different things on different sheets
The same letters are reused across disciplines. Read an abbreviation by the sheet it is on, and by its context, before you look it up.
| Abbr. | One meaning | Another meaning |
|---|---|---|
| EF | Each face (structural) | Exhaust fan (mechanical) |
| EA | Each (general notes) | Exhaust air (mechanical) |
| RCP | Reflected ceiling plan (architectural) | Reinforced concrete pipe (civil) |
| PT | Post-tensioned or pressure-treated (structural) | Paint or porcelain tile (finish schedules) |
| SD | Storm drain (civil) | Smoke damper or smoke detector (mechanical) |
| CB | Catch basin (civil) | Circuit breaker (electrical) |
| WP | Waterproofing (architectural) | Weatherproof (electrical) |
| W | Wide flange beam (structural) | Watt or wire (electrical) |
| WC | Water closet (plumbing) | Wall covering (finishes) |
| FD | Floor drain (plumbing) | Fire damper (mechanical) |
| AC | Asphalt concrete (civil) | Air conditioning (mechanical) |
| TOS | Top of steel | Top of slab |
How to read callouts that combine abbreviations
Abbreviations are usually strung together in a callout. These are read left to right:
| Callout | Reads as |
|---|---|
| #5 @ 12" O.C. EW T&B | Number 5 rebar, 12 inches on center, each way, top and bottom: four layers of bars |
| T/FTG EL. 96'-0" | Top of footing at elevation 96 feet 0 inches |
| W12x26 | Wide flange beam, 12 inches nominal depth, 26 pounds per foot |
| L4x4x3/8 LLV | Steel angle, 4 by 4 inches, 3/8 inch thick, long leg vertical |
| 5/8" TYPE X GWB EA SIDE | 5/8 inch fire-rated gypsum wallboard on each side of the stud |
| +42" AFF | Mounted 42 inches above finished floor |
| STA 10+50 | 1,050 feet along the baseline from station 0+00 |
| 8" PVC SS @ 1.0% INV 92.45 | 8 inch PVC sanitary sewer at 1 percent slope, invert elevation 92.45 feet |
Bar sizes, weights and lap lengths for callouts like the first one are in the rebar sizes and weight chart.
Where to find a drawing set's abbreviation legend
Every set defines its own abbreviations, and firms differ, so the legend in the set wins over any list, including this one. Under the US National CAD Standard, sheet numbers start with a discipline letter, and the legend is usually on the first sheet of the G or A series:
| Letter | Discipline | Letter | Discipline |
|---|---|---|---|
| G | General: cover, index, abbreviations, symbols | A | Architectural |
| C | Civil | I | Interiors |
| L | Landscape | Q | Equipment |
| S | Structural | F | Fire protection |
| P | Plumbing | M | Mechanical |
| E | Electrical | T | Telecommunications |
Specification sections also define terms, usually in Division 01. When the drawings and the specification disagree, the contract decides which governs, and the question belongs in an RFI before bid day. To find which division a material falls under, see the CSI divisions list.
Getting the whole set taken off
Our estimators read full drawing sets every day, notes, legends and schedules included, and deliver marked-up plans with an editable Excel workbook, usually in 24 to 48 hours. See how to read a construction estimate, how we estimate, or send the drawings for a free quote.
Common questions
Typical. The detail or dimension applies at every location with the same condition, not only where it is drawn, so count every occurrence in the takeoff.
Unless noted otherwise. It sets the default for the sheet; any location with a different note is the exception.
U.N.O., UNO and UON all mean unless noted otherwise. A note such as "5/8" gypsum board U.N.O." means every wall gets 5/8" board except the ones the drawings call out differently, so the estimator counts the exceptions first and prices the rest at the default.
Above finished floor. Mounting heights of outlets, switches, fixtures and accessories are given in inches AFF.
Not in contract. The item is shown for coordination only and is not part of the work being bid, so leave it out of the takeoff.
Owner furnished, contractor installed. The owner buys the item and the contractor installs it, so price the labor but not the material. OFOI means owner furnished, owner installed.
EW is each way: reinforcing in both directions. EF is each face: reinforcing on both faces of a wall. Both double the bars to take off.
Top of wall, usually followed by an elevation. Similar callouts are TOF (top of footing), TOC (top of concrete), TOS (top of steel or slab) and BOF (bottom of footing).
Similar. The location is built like the referenced detail with minor differences, which should be checked before copying its quantities.
On architectural sheets, reflected ceiling plan. On civil sheets, reinforced concrete pipe.
In the abbreviation legend, usually on the first general (G) or architectural (A) sheet, and sometimes on the first sheet of each discipline. The set's own legend overrides any general list.